3.5 Number of products minimum产品小值

  3 apparatus minimum must be tested.三个仪器的小值必须被检查

  3.6 During the test测试时

  14 consecutive drop tests on all the faces as defined in the diagram : one on each face and corner while the apparatus is working. Even if the apparatus doesn‘t fall on the face or corner desired, the drop isn‘t done again.

  所有表面上的14个连续下落测试如图表中定义的:当仪器在运转中,每一个表面和角落上的.即使仪器没有下落在理想的表面或角落上,下落也无须再做1次

  The battery, unless a contrary request, must not be fixed with an external tool. 除非有相反的要求,否则电池组无须固定在外部工具上

  Between each drop, the specimen shall be visually examinated and electrically and mechanically checked. 在每一次下落间, 样品外观要检查,电力方面和机械方面也要检查

  Points to check :

  o Switch on and off the mobile开关手机

  o All buttons/keys are functioning.所有的按钮都要检查是否能使用

  o Transaction with SIM card处理sim卡

  o Check that all the pixels are functional (Use the specified function of the software for this test. Example for BE1 and BE3, type 000000* then choose the function "checker"). 检查所有像素[使用供测试用的专门软间,比如be1,be3]

  o Check the communication检查通讯

  4. JUDGEMENT判断

  The specimen shall be visually examinated and electrically and mechanically checked after each drop. 在每一次下落后,样品外观要检查,电力方面和机械方面也要检查

  o Checking performances of equipment.检查设备的性能

  - Possibility to switch on and off the mobile开关手机

  - Mobile stay switched on alone手机保持单独打开

  - All buttons/keys are functioning. 所有的按钮都要检查是否能使用

  - Transaction with SIM card possible. 处理sim卡

  - Check that all the pixels are functional (Use the specified function of the software for this test. Example for BE1 and BE3, type 000000* then choose the function "checker"). 检查所有像素[使用供测试用的专门软间,比如be1,be3]

  - Check that communication is possible.检查通讯

  o Check the aspect of the equipment after the falling:在下落后,检查仪器的每一方面

  - no injury can be caused due to damage.由于破坏,无损坏被引起

  - damage due to casing must not affect operation.由于装箱的破坏必须不影响操作 interface with all the accessories still functional和所有附件的接口依然有功能。